+6018-789 7171     |       jason@vivogroups.com  

Methadone (MTD) Rapid Test Panel - Powder

Previous 113 / 158 Next

Methadone (MTD) Rapid Test Panel - Powder JusChek Drug of Abuse Rapid Test


¡¾SUMMARY¡¿
Methadone is a narcotic analgesic prescribed for the management of moderate to severe pain and for the treatment of opiate dependence (heroin, Vicodin, Percocet, morphine). The pharmacology of oral methadone is very different from IV methadone. Oral methadone is partially stored in the liver for later use. IV methadone acts more like heroin. In most states you must go to a pain clinic or a methadone maintenance clinic to be prescribed methadone.
Methadone is a long acting pain reliever producing effects that last from twelve to forty-eight hours. Ideally, methadone frees the client from the pressures of obtaining illegal heroin, from the dangers of injection, and from the emotional roller coaster that most opiates produce. Methadone, if taken for long periods and at large doses, can lead to a very long withdrawal period. The withdrawals from methadone are more prolonged and troublesome than those provoked by heroin cessation, yet the substitution and phased removal of methadone is an acceptable method of detoxification for patients and therapists.
The Methadone contained within the MTD Rapid Test Panel yields a positive result when the MTD concentration exceeds 300ng/ml.
 
 
¡¾DIRECTIONS FOR USE¡¿
Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.
Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES
1. Wipe with the panel over the surface in which the drugs are expected.
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer.
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

 
FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.
6. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DMT-X14

Methadone (MTD) Rapid Test Panel

Powder

Panel

25 T

300 ng/mL

CE


Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version