+6018-789 7171     |       jason@vivogroups.com  

¦Á-Pyrrolidinovalerophenone (¦Á-PVP ) Rapid Test Panel - Powder

Previous 104 / 158 Next

¦Á-Pyrrolidinovalerophenone (¦Á-PVP ) Rapid Test Panel - Powder JusChek Drug of Abuse Rapid Test


¡¾SUMMARY¡¿
Alpha-Pyrrolidinovalerophenone (also known as α-PVP, A-PVP, Alpha-PVP, and Flakka) is a synthetic stimulant substance of the cathinone and pyrrolidine chemical classes. It generally comes in the form of either a crystalline powder or crystallized shards which users can ingest to produce powerful but short-lived euphoric stimulant effects which are comparable to those of methamphetamine and cocaine when insufflated or vaporized. α-PVP has been reported to be the cause, or a significant contributory cause of death in suicides and overdoses caused by combinations of drugs. It has also been linked to at least one death where it was combined with pentedrone and caused heart failure.
The α-PVP Rapid Test Panel (Powder) is a rapid powder screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect α-PVP. The α-PVP Rapid Test Panel (Powder) yields a positive result when the concentration of α-PVP exceeds 1000 ng/ml.

¡¾DIRECTIONS FOR USE¡¿
Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.
Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES
1.Wipe with the panel over the surface in which the drugs are expected.
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer.
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.


FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.
6. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

FOR SOLIDS WITH SWAB
1. Take out the buffer vial and open the lid. Place the swab into the tube for 5-10 seconds to allow swab head to be thoroughly soaked in the buffer.
2. Take out the swab and wipe the surface solids gently at least 3 times, and then insert the swab into buffer vial and mix well for at least 1 minute. Squeeze the swab several times by compressing the outside walls of the vial against the swab to mix well. Finally squeeze the swab to make most of the solution stay in the buffer vial and remove the swab. Use solution thus obtained as specimen.
3. Take off the cap of dropper cap.
4. Fill the solution with dissolved substances into the protection cover.
5. Insert the Test Panel slowly and carefully into the protection cover with buffer.
6. Wait for control line to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DAP-X14

α-Pyrrolidinovalerophenone (α-PVP ) Rapid Test Panel

Powder

Panel

25 T

1000 ng/mL

CE