ETG Rapid Test Cassette - WB/S/P JusChek Drug of Abuse Rapid Test


¡¾SUMMARY¡¿
Ethyl Glucuronide (ETG) is a metabolite of ethyl alcohol which is formed in the body byglucuronidation following exposure to ethanol, such as by drinking alcoholic beverages. Itisused as a biomarker to test for ethanol use and to monitor alcohol abstinence in situationswhere drinking is prohibited, such as in the military, in professional monitoring programs(health professionals, attorneys, airline pilots in recovery from addictions), in schools, inliver transplant clinics, or in recovering alcoholic patients. ETG can be measured in urine by Traditional laboratory methods (GC/MS or LC/MS) upto approximately 80 hours after ethanol is ingested (greatly dependent on the amount of alcoholic and non-alcoholic drinks). ETG is a more accurate indicator of therecent exposure to alcohol than measuring for the presence of ethanol itself.
The Ethyl Glucuronide Rapid Test Cassette (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of ethyl glucuronide in human urine. The Ethyl Glucuronide Rapid Test Strip (Urine) yields a positive result when the Ethyl Glucuronide in urine exceeds 500 ng/mL.
 
 
¡¾DIRECTIONS FOR USE¡¿
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
For serum or plasma specimen:
1. Bring the pouch to room temperature (15-30¡æ) before opening it. Remove the cassette from the sealed pouch and use it within one hour.
2. Place the cassette on a clean and level surface. Hold the dropper vertically and transfer 1 full drop of serum or plasma (approximately 40 μl), then add 2 drops of buffer (approximately 80 μl) to the specimen well of the cassette, and then start the timer. Avoid trapping air bubbles in the specimen well. See illustration below.
3. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not interpret the result after 10 minutes.
 

 
1 Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
2 Place the cassette on a clean and level surface.
For Venipuncture Whole blood specimen:
Hold the dropper vertically and transfer 1 drop of whole blood (approximately 40 μl) to the specimen well, then add 2 drops of buffer (approximately 80 μl), and start the timer. See illustration below.
For Fingerstick Whole blood specimen:
To use a capillary tube: Fill the capillary tube and transfer approximately 40 μl of fingerstick Whole blood specimen to the specimen area of test cassette, then add 2 drops of buffer(approximately 80 μl) and start the timer. See illustration below.
3 Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DET-402

ETG Rapid Test Cassette

WB/S/P

Cassette

40 T

500 ng/mL

CE