¡¾SUMMARY¡¿
3,4-Methylenedioxyamphetamine (MDA), also known as tenamfetamine (INN), or with the street name ''Sally'' or ''Sass'' or ''Sass-a-frass'', is a psychedelic and entactogenic drug of the phenethylamine and amphetamine chemical classes. It is mainly used as a recreational drug, an entheogen, and a tool in use to supplement various types of practices for transcendence, including in meditation, psychonautics, and as an agent in psychedelic psychotherapy. It was first synthesized by G. Mannish and W. Jacobson in 1910. There are about 20 different synthetic routes described in the literature for its preparation.The MDA Rapid Test Cassette (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of 3,4-Methylenedioxyamphetamine in urine. The MDA Rapid Test Cassette (Urine) yields a positive result when Amphetamines in urine exceed 500 ng/mL.
 
¡¾DIRECTIONS FOR USE¡¿
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
For serum or plasma specimen:
1. Bring the pouch to room temperature (15-30¡æ) before opening it. Remove the cassette from the sealed pouch and use it within one hour.
2. Place the cassette on a clean and level surface. Hold the dropper vertically and transfer 1 full drop of serum or plasma (approximately 40 μl), then add 2 drops of buffer (approximately 80 μl) to the specimen well of the cassette, and then start the timer. Avoid trapping air bubbles in the specimen well. See illustration below.
3. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not interpret the result after 10 minutes.
 
 
For whole blood specimen:
4. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
5. Place the cassette on a clean and level surface.
For Venipuncture Whole Bloodspecimen:
 Hold the dropper vertically and transfer 1 drop of whole blood(approximately 40 μl) to the specimen well, then add 2 drops of buffer (approximately 80 μl), and start the timer. See illustration below.
For Fingerstick Whole Blood specimen:
 To use a capillary tube: Fill the capillary tube and transfer approximately 40 μl of fingerstick whole blood specimen to the specimen area of test cassette, then add2 drops of buffer(approximately 80 μl) and start the timer. See illustration below.
6. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
 
 
 

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DMDA-402

MDA Rapid Test Cassette

WB/S/P

Cassette

40 T

80 ng/mL

CE