Mephedrone HCI(MEP) Rapid Test - Urine

Previous 32 / 158 Next

Mephedrone HCI(MEP) Rapid Test - Urine JusChek Drug of Abuse Rapid Test


¡¾SUMMARY¡¿
Mephedrone, also known as 4-methylmethcathinone (4-MMC) or 4-methylephedrone is a synthetic stimulant drug of the amphetamine and cathinone classes. Slang names includedrone, M-CAT, White Magic and meow meow.It is chemically similar to the cathinonecompounds found in the khat plant of eastern Africa.
Mephedrone comes in the form of tablets or a powder, which users can swallow, snort or inject,producing similar effects to MDMA, amphetamines and cocaine. In addition to its stimulant effects, mephedrone produces side effects, of which teeth grinding are the most common.

¡¾DIRECTIONS FOR CASSETTE USE¡¿
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

¡¾DIRECTIONS FOR PANEL USE¡¿
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but
do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

¡¾DIRECTIONS FOR DIPSTICK USE¡¿
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

 

 

 

 

 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

DMEP-102

Mephedrone HCI (MEP) Rapid Test Cassette

Urine

Cassette

40 T

100 ng/mL*

CE

DMEP-114

Mephedrone HCI(MEP) Rapid Test Panel

Urine

Panel

40 T

CE

DMEP-101

Mephedrone HCI(MEP) Rapid Test Dipstick

Urine

Dipstick

50 T

CE